Present Used Methods for Measuring Dissolved Oxygen Concentration at Wastewater Treatment Plants

Treść / Zawartość
Warianty tytułu
Języki publikacji
PL
Abstrakty
EN
The article presents common used methods for measuring dissolved oxygen concentration at wastewater facilities. The described methods include Winkler titration and instrumental measurements, such as electrochemical sensors and more recent developed optical ones. The principles, analysis procedures as well as advantages and drawbacks of the methods were discussed. Furthermore, the valid ISO and PN-EN standards for dissolved oxygen measurements were shortly presented with emphasis on the recent changes concerning standards for the optical sensor method. As the results of a survey conducted among wastewater treatment plant operators in southern Poland reveal, optical sensors are being currently preferred in on-line applications due to their enhanced properties in comparison to other measurements methods.(original abstract)
Rocznik
Numer
Strony
431--440
Opis fizyczny
Twórcy
  • University of Agriculture in Krakow
  • University of Agriculture in Krakow
  • University of Agriculture in Krakow
  • University of Agriculture in Krakow
Bibliografia
  • Bell, S., Dunand, F., Schubert, M., Koenig, R. (2012). Optische Sauerstoffmessung in Kraftwerk. VGB Powertech, 9, 1-6.
  • Chu, Ch.-S., Lo, Y.-L., Sung, T.-W. (2011). Review on recent development of fluorescent oxygen and carbon dioxide optical fiber sensors. Photonic Sensors, 1/3, 234-250. DOI: 10.1007/s13320-011-0025-4.
  • Dojlido, J., Zerbe, J. (1997). Instrumentalne metody badania wody i ścieków.
  • Warszawa: Arkady. Minczewski, J., Marczenko, Z. (2011). Chemia analityczna. T. 2. Chemiczne metody analizy ilościowej. Warszawa: PWN.
  • Wierzbicki, L. (1997). Analiza wody i ścieków. Białystok: Wyd. Politechniki Baiłostockiej.
  • Winkler, L. (1888). Die Bestimmung im Wasser gelösten Sauerstoffes. Berichte der Deutschen chemischen Gesellschaft zu Berlin, 21, Nr. 2, 2843-2855. DOI: 10.1002/cber.188802102122
  • Younos, T., Parece, T.E. (2015), Advances in watershed science and assessment. Cham Heidelberg New York Dodrecht London: Springer. DOI 10.1007/978-3-319- 14212-8.
  • Application Data Sheet ADS 4950-01/ rev.G. (2009). Water and wastewater Industry. Dissolved oxygen measurement in wastewater treatment. Emerson Process Management Company.
  • Application Note AN-D1. (2004). Dissolved oxygen measurement in a wastewater treatment plant. Hach Company.
  • PN-EN 25813:1997. Jakość wody - Oznaczenie tlenu rozpuszczonego - Metoda jodometryczna.
  • PN-EN ISO 5814:2013-04. Jakość wody - Oznaczenie tlenu rozpuszczonego - Metoda z czujnikiem elektrochemicznym.
  • PN-EN 25814:1999. Jakość wody - Oznaczenie tlenu rozpuszczonego - Metoda z czujnikiem elektrochemicznym.
  • ISO 17289:2014. Water quality - Determination of dissolved oxygen - Optical sensor method.