Safety Analysis of Coolant Needed Supply for Spent Fuel Pool in Light of Fukushima Accident

Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The Fukushima accident shows us that not only the core and reactor could make problems during unexpected events but also Spent Fuel Pool (SFP). That accident encouraged many experts to reconsider safety features in this area of Nuclear Power Plants (NPP) and to be more mindful of this potential problem. Preparing precise analysis of such accidents could provide important information about possible consequences and bring up essential solutions about how to improve SFP fuel management and safety systems related with the fuel storage process. This paper delivers analysis based on the Fukushima SFP unit 4 accident from March 11th 2011. The Fukushima type accident was caused by a lack of heat reception: water vaporization was the only way for heat to escape from SFP. Critical to avoid serious consequences in that situation is to know when and how much water must be provided by the operator to the SFP to ensure the assembly is submerged into a coolant. During this accident the SFP was almost full, 1530 of 1560 spots were taken and instruments, safety or safety-related systems like heat exchangers were not available. (original abstract)
Czasopismo
Rocznik
Numer
Strony
9450--9457
Opis fizyczny
Twórcy
  • AGH University of Science and Technology Kraków, Poland
  • AGH University of Science and Technology Kraków, Poland
  • AGH University of Science and Technology Kraków, Poland
Bibliografia
  • [1] Best, F., and Pisano, N., The Propagation of Self-Sustaining Zirconium Oxidation in a Drained Spent Fuel Storage Pool. Transactions of the American Nuclear Society, 45, 133-134, 1983.
  • [2] Randall Gauntt, Donald Kalinich, Jeff Cardoni, Jesse Phillips, SANDIA REPORT SAND2012-6173, Fukushima Daiichi Accident Study (Status as of April 2012) July 2012.
  • [3] Nuclear Emergency Response Headquarters Government of Japan, Report of Japanese Government to the IAEA Ministerial Conference on Nuclear Safety - The Accident at TEPCO's Fukushima Nuclear Power Stations, June 2011
  • [4] Dean Wang, IanC.Gauld, Graydon L. Yoder, LarryJ. Ott, Study of Fukushima Daiichi Nuclear Power Station Unit 4 Spent-Fuel Pool, Oak Ridge National Laboratory, January 2012.
  • [5] Andrew Barto Y. James Chang, Keith Compton, Hossein Esmaili, Donald Helton, Andrew Murphy, Andrew Nosek, Jose Pires, Fred Schofer, Brian Wagner, Consequence Study of a Beyond-DesignBasis Earthquake Affecting the Spent Fuel Pool for a U.S. Mark I Boiling Water Reactor Draft Report, June 2013
  • [6] Division of Systems Analysis and Regulatory Effectiveness Office of Nuclear Regulatory Research, MELCOR Computer Code Manuals Vol. 2: Reference Manual, Version 2.0, September 2008.
  • [7] Division of Systems Analysis and Regulatory Effectiveness Office of Nuclear Regulatory Research, MELCOR Computer Code Manuals, Vol. 1: Primer and Users' Guide, Version 2.0, September 2008