PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2020 | 3 | 206--215
Tytuł artykułu

Influence of the Volumetric Expenditure of Air Supplied to the Longwall Through the "Y" Ventilation System on the Location of an Area at the Risk of an Endogenic Fire

Autorzy
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In the case of longwall ventilation, in the underground hard coal mines, a phenomenon related to the migration of a certain amount of the air stream supplied to the longwall deep into goaf zones occurs. One of the wall ventilation systems, in which this phenomenon is quite intense, is the so called "Y" ventilation system. This migration is immensely unfavorable because it can lead to the self-heating process of coal left in a goaf and, consequently, to an endogenous fire. Such a fire is a great threat to both the safety and continuity of operation processes. For this reason, various activities are undertaken to prevent such a fire from occurring in goaf zones. One solution is a method presented in this article. It aims at determining an area in goaf zones, where an endogenous fire may occur. The study focused on the longwall ventilated with the Y system. This area was determined based on two criteria, namely air velocity and oxygen content. The study was carried out for various volumes of air supplied to the longwall. Therefore, the purpose of the study was to develop research methodology and determine the location of an area at the risk of an endogenous fire. The location of this area was determined for three different volume expenditures of air supplied to the longwall ventilated with the Y system. (original abstract)
Rocznik
Tom
3
Strony
206--215
Opis fizyczny
Twórcy
  • Silesian University of Technology, Poland
Bibliografia
  • ANSYS. (2011). Ansys Theory Guide; ANSYS, Inc.: Canonsburg, PA 15317., USA.
  • Brodny, J. and Tutak, M. (2019). Forecasting the distribution of methane concentration levels in mine headings by means of model-based tests and in-situ measurements. Archives of Control Sciences, 29(1), pp. 25-39.
  • Brodny, J. and Tutak, M. (2018). Determination of the zone with a particularly high risk of endogenous fires in the goaves of a longwall with caving. Journal of Applied Fluid Mechanics, 11(3), pp. 545-553.
  • Brodny, J.; Tutak, M. and John, A. (2018). The impact of airway geometry on the distribution of methane concentrations at the outlet from a longwall. Mechanika, 24(5), pp. 695-702.
  • Brodny, J. and Tutak, M. (2016a). Analysis of gases emitted into the atmosphere during an endogenous fire. Proceedings of 16th International Multidisciplinary Scientific GeoConference SGEM 2016, pp. 75-82. DOI: 10.5593/SGEM2016/HB43/S06.011.
  • Brodny, J. and Tutak, M. (2016b). The impact of the flow volume ventilation to the location of the special hazard spontaneous fire zone in goaf with caving of operating longwalls. Proceedings of the 16th International Multidisciplinary Scientific GeoConference. SGEM 2016, pp. 897-904, doi:10.5593/SGEM2016/B12/S03.115.
  • Dai, G.; Zhang, S. and Tang, M. (2012) Determination of spontaneous combustion "three zones" in goaf of no. 713 fully mechanized longwall of qinan coal mine. AGH J. Min. Geoengin, 36, 99-113.
  • Kurnia, J.C., Sasmito, A.P. and Mujumdar; A.S. (2014). Simulation of a novel intermittent ventilation system for underground mines. Tunnelling and Underground Space Technology, 42, pp. 206-215.
  • Kurnia, J.C., Xu, P. and Sasmito, A. (2016). A novel concept of enhanced gas recovery strategy from ventilation air methane in underground coal mines e A computational investigation. Journal of Natural Gas Science and Engineering, 35, pp. 661-672.
  • Li, Z.X.; Wu, Q. and Xiao, Y.N. (2008). Numerical simulation of coupling mechanism of coal spontaneous combustion and gas effusion in goaf. J. China Univ. Min. Technol, 37, 38-42.
  • Szlązak, J. (2001). The determination of a co-efficient of longwall gob permeability. Arch. Min. Sci., 46, 451-468.
  • Szurgacz, D.; Sobik, L. and Brodny, J. (2019). Integrated method of reducing the threat of endogenous fires in hard coal mines. E3S Web of Conferences, 105,01013.
  • Tutak, M. and Brodny, J. (2019). The Impact of the Strength of Roof Rocks on the Extent of the Zone with a High Risk of Spontaneous Coal Combustion for Fully Powered Longwalls Ventilated with the Y-Type System - Case Study. Appl. Sci. 9, 5315.
  • Tutak, M. and Brodny, J.(2018). Impact of type of the roof rocks on location and range of endogenous fires particular hazard zone by in goaf with caving. E3S Web Conferences Volume 29. DOI:10.1051/e3sconf/20182900005.
  • Tutak, M. and Brodny, J. (2017a): Analysis of Influence of Goaf Sealing from Tailgate On the Me-thane Concentration at the Outlet from the Longwall. IOP Conf. Series: Earth and Environmental Science 95 042025. doi:10.1088/1755-1315/95/4/042025.
  • Tutak, M. and Brodny, J. (2017b): Determination of Particular Endogenous Fires Hazard Zones in Goaf with Caving of Longwall. IOP Conf. Series: Earth and Environmental Science 95 (2017) 042026 DOI:10.1088/1755-1315/95/4/042026.
  • Xu, Q.; Yang, S.Q.; Wang, C.; Chu, T.X.; Ma, W.; Huang, J. (2010). Numerical simulation of gas flow law in stope under stereo gas drainage. J. Min. Saf. Eng. 27, pp. 62-66.
  • Wyższy Urząd Górniczy, (2003-2018). Niebezpieczne zdarzenia, Available at: http://www.wug.gov.pl/bhp/zdarzenia [Accessed 1 May 2020].
  • Wang, Y.; Zhang, X.; Sugai, Y. and Sasaki, K. (2015). A Study on Preventing Spontaneous Combustion of Residual Coal in a Coal Mine Goaf. J. Geol. Res., 712349.
  • Yuan, L. and Smith, A.C. (2008). Numerical study on effects of coal propertis on spontanous heating in longwall gob areas. Fuel, 87, 3409-3419.
  • Yuan, L. and Smith, A.C. (2009). CFD modeling of spontanous heating in a large-scale coal chamber. J. Loss Prev. Process Ind., 22, pp. 426-433.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.ekon-element-000171608747

Zgłoszenie zostało wysłane

Zgłoszenie zostało wysłane

Musisz być zalogowany aby pisać komentarze.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.